DC Drives
          
 
Analog DC Drives
Standard Features
Modular construction for easy maintenance & ready for mounting inside a panel.
Both Armature Voltage & Tacho Feedback available as Site Selectable option.
IR compensation for Armature feedback.
Fault status indication by LED’s.
Built in Test points for maintenance.
Control through external process variable / reference signal like 4 to 20 mA & 0 to 10 V DC.
   
 
  Optional Features  
 

Panel enclosure with necessary protections, switchgear, indications, controls, chokes, PID, Fast acting fuses internally wired to the components and terminal

Multi drive system with individual and Synchronisation mode
Fault annunciation
Custom built system
 
   
  Applications  
 
Wire & Cable industry viz. Extruder, Take-up, Pay-off, Capstan, Unwinder, winder, G.T., D.T., etc.
Steel Industry
Mill Drive viz. Rolling mill, Tyre mill, flattening mill, etc.
Machining center viz. VTL, Gig Boaring, Spindle, Gear grinding/shaving, hobbing, Axis, Horizontal boaring, etc.
Chemical industry
Textile industry
Cement Industry
 
     
  Katcon make Analog DC Drive Modules  
  Available in the following standard series  
 
1. MD Series 1 Phase, Full Wave Half Controlled, Upto 2 Amps
2. F Series 1 Phase, Full Wave Full Controlled, Upto 60 Amps
3. F RR Series 1 Phase, Full Wave Full Controlled, Regenerative, Upto 60 Amps
4. M Series 3 Phase, Full Wave Full Controlled, Upto 130 Amps
5. M -RR Series 3 Phase, Full Wave Full Controlled, Regenerative, Upto 100 Amps
6. D Series 3 Phase, Full Wave Full Controlled, Upto 1200 Amps
 
     
  Technical Specifications  
 
Rating 'F' Series - Upto 60 Amps
'F' Series - Upto 60 Amps
M Series - Upto 130 Amps 'M-RR" Series - Upto 100 Amps
Input AC Supply 1 Ph, 230 V AC + 10%, 50Hz + 2 Hz
2 pH, 415 V AC + 10% 50 Hz + 2 Hz
3 pH 415 V Ac + 10%, 50 Hz + 2 Hz, 4 Wire 3 pH 415 V AC + 10%, 50 Hz + 2 Hz, 4 Wire
Output Voltage 0-180 V DC To Armature
0-380 V DC To Armature
200 V DC to Field
0- 440 V DC To Armature
200 V DC To Field
0-440 V Dc To Armature
200 V DC To Field
Feedback (Site selectable) Armature Voltage / Tacho
(Only Tacho F/B for RR Drives
Armature Voltage / Tacho Tacho Feedback
Speed regulation +1% with Tacho Feedback or
+2.5% with Armature voltage Feedback
+ 1% with Tacho Feedback Or
+ 2.5 with Armature Voltage Feedback
+ 1% with Tacho Feedback
Speed range 20 : 1 of Base Speed 50 : 1 Base Speed 50 : 1 Base Speed
Protections With Protection by RC Snubbers, Current Limit, Field Failure Relay with Protection by RC Snubbers, Current Limit, Field Failure Relay, Tacho Failure Trip, Over Speed Trip Protection by RC Snubbers
FWD/REV Current Limit, Field Failure Relay
Adjustments Current Limit, Max. Speed Stability, Acceleration & Deceleration Rate, IR Compensation (For Armature Voltage Feedback) Current Limit, Max. Speed, Acceleration & Deceleration Rate, Stability, Over Current Trip, IR Compensation, Over Speed Trip, Tacho Fall Trip Current Limit (FWD/REV),
Max Speed, Stability Max.o/p
Led Indications For 1Q Drives:
+15 v Healthy Current Limit, Motor On
For 4 Q Drives:
+15 v Healthy Motor On, PWD REV
Power On, Tacho Fall Trip, Over Current, Trip, Over Speed Trip, Current Limit, Motor ON Power ON Motor On FWD/REV
Loading Conditions 125% for 10 Seconds                110% for 2 Hours               100% continuous
Environmental Conditions  
Ambient Temp
45% C MAx
Humidity
95% Max. Non Condensing
Attitude
100Mtrs Max. Above MSL
Construction Open Execution Module suitable for mounting inside a panel
Models F-12, F-30, F-40, F-60,
FRR-30, FRR-40, FRR-60
M/15, M/40, M/80, M/100, M/130
D/200, D/300 upto D/1200
M-RR/15, M-RR/40, M-RR/80, M-RR/100
 
     
  Katcon make MD Series DC Drives  
  Model 1:
Open execution type ready to mount in 3U rack
Model 2:
Aluminium Sub Rack 3U x 155 ready to mount on chassis
 
     
 
MD Series DC Drives
Standard Features
Fully solid state power control
Armature voltage & current feedback to control the motor speed accurately
IR compensation for Armature feedback
Control through external 0 to 10 V.D.C. Signal with isolation of 2kV
Local / Remote selection through D/P switches
Easy access to all required preset settings & led indications
Set speed Pot on front plate for local mode
    
 
     
  Katcon MD Series Technical Specifications  
 
Rating 0.75H.p. Max (2Amps)
Input supply 1 Phase, 230 V A.C. + 10% 50 Hz + 2Hz
Output voltage 0-180 V.D.C.
Regulation 2.5% on Armature Feedback
Reference 0 to + 10 V.D.C., 2kV isolation between circuit ground & source ground
Enable 24 V.D.C. Signal from PLC or Potential free ‘NO’ contact
Local Reference Set speed pot provided on front
Local / Remote DIP switches are provided to select set point & enable in case of Local & remote coperations.
Preset Adjustments IR compensation for load regulation
N max for speed adjustment
Off-set for Zero speed
I Imt to set output current limit
Led Induction Drive enable
Power on
I Imt
‘Armature Open’ fault trip'
Protections dv/dt protection by RC network
Current limit
Armature open
Isolated input reference
Relay output Potential free contact for drive healthy 2 amp/ 230V AC
External Connector Type Phoenix plug in type 2.5 Sq. mm
Mounting Construction 1. Size : 45 x 125 x 140 mm (LxHxD) open execution ready to mount in 3U Rack
2. Aluminium sub-rack 3 U x 155 mm depth ready to mount on chassis / tray
Operating temp max. upto 45°C
 
     
 
Download product catalogue
 
     
Copyright © 2010 by Kat Controls Pvt. Ltd. All Rights Reserved.